| Products |
|
 |
K3 Internal Refrigerator Water Filters |
|
|
|

|

|
Click to enlarge image
|
Features
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine, Taste and Odor and Particulate Class I ; and against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Asbestos, Cyst, Turbidity, Atrazine, Benzene and Lindane.
Specification
|
Substance
|
Average Influent Mg/L
|
Influent Challenge Concentration mg/L
|
Maximum permissible product water concentration mg/L
|
Reduction requirement
|
Average Product water Concentration
|
Average % Reduction
|
Max. Effluent Mg/L
|
|
Chlorine Taste and Odor
|
1.9
|
2.0 mg/L ± 10%
|
N/A
|
50%
|
0.05
|
97.4
|
0.06
|
|
Particulate Class I Particles >0.5μm to 1μm
|
14000000/mL
|
at least 10,000 particles/mL
|
N/A
|
≥85%
|
256000/mL
|
98.0
|
420000/mL
|
|
Lead pH 6.5
|
0.140
|
0.15 ± 10%
|
0.010
|
N/A
|
0.001
|
99.3
|
0.001
|
|
Lead pH 8.5
|
0.150
|
0.15 ± 10%
|
0.010
|
N/A
|
0.001
|
99.3
|
0.001
|
|
Mercury pH 6.5
|
0.0057
|
0.006± 10%
|
0.002
|
N/A
|
0.0002
|
96.5
|
0.0002
|
|
Mercury pH 8.5
|
0.006
|
0.006± 10%
|
0.002
|
N/A
|
0.0002
|
96.4
|
0.0003
|
|
Atrazine
|
0.0093
|
0.009± 10%
|
0.003
|
N/A
|
0.0005
|
94.6
|
0.0005
|
|
Benzene
|
0.015
|
0.015± 10%
|
0.005
|
N/A
|
0.0005
|
96.7
|
0.0005
|
|
Asbestos
|
130 MFL
|
107 to 108 fibers/L; fibers greater than 10 m in length
|
N/A
|
99%
|
0.17 MFC
|
99.0
|
0.17 MFC
|
|
Cyst (microsphere)
|
96000/L
|
Minimum 50,000/L
|
N/A
|
99.95%
|
2/L
|
99.99
|
3/L
|
|
Lindane
|
0.0019
|
0.002± 10%
|
0.0002
|
N/A
|
0.00002
|
99.0
|
0.00002
|
|
Turbidity
|
11 NTU
|
11 ± 1 NTU
|
0.5 NTU
|
N/A
|
0.1 NTU
|
99.1
|
0.1 NTU
|
Operating conditions
- Flow rate : 0.5 GPM(1.9LPM)
- Pressure : 30 - 100 PSI (207-689kPa)
- Temperature : 34-100 F (1-38 °C)
- Service life : 6 Months
- Capacity : 300 Gallons (1,136 Liters)
- Function : Chemical/Mechanical Reduction
- Flushing : 5 Minutes
Operating Notices
- Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
- For cold water only.
- Replace whole filter for every 6 months
- The testing was performed under standard laboratory conditions, actual performance may vary.
- Check for compliance with the state and local laws and regulations.
- Systems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
|
|
|
|
| |
|
|
|